LINKMED® HL7 TCP/IP Transmitter_
Configuration

LINKMED® HL7 TCP/IP Transmitter other Options (Continue)

  • Disconnect after transmitting one file check box: This feature is used for HL7 query interface, the server will response with query response ACK at later time
  • Copy file to LTSENT folder after sending check box: Check this box allows the Transmitter to copy the HL7 message into this folder after receiving message acknowledgements from the server (uses to change study order status to completed)
  • The "CantSend" feature of the Transmitter allows the message being rejected to move out of the message queue and allows the transmitter to send other messages in the queue. You specify number of tries in the "Move file to …\CantSend\ folder after number of tries" box before moving the message out of the queue. The message being move out of the queue when the Transmitter reach the time limit waiting for message Acknowledgements and number of trying to send that message.
    Note: If you are activating this feature make sure that you have plan to reconcile the CantSend messages later, either by manually reconcile or use the LINKMED® interface utility to automatethe resend of those messages, otherwise leave it at default (Never)
  • Do not check the Length Encode check box, this feature is for use in European countries and not required for US and North America
  • For HL7 query interface: click on Options button to the right of the "Validate HL7 message" column to access the Transmitter HL7 Validation Parameters
  • Click on the check box at " Write ACK to Files:" then click on the "..." and browse to the directory of your interface Inbound Input location for HL7 query response message (Mapper inbound input directory)
  • For HL7 Billing interface (DFT^P03): LINK recommended increase the Time delay to 20 seconds from the Transmitter default 4 seconds, the increase in waiting for ACK time delay allows hospital financial system enough time to process the billing message and sends ACK response


LINKMED® HL7 TCP/IP Transmitter HL7 Query Option Configuration

..........................................................................................................................................................

 

© Copyright LINK Medical Computing, Inc. All rights reserved Terms of Use.