LINKMED® HL7 TCP/IP Transmitter (Outbound communication
client) is used to transmit HL7 result or query message to
HIS or Clinical systems. The HL7 TCP/IP transmitter monitors
result or query folder for file, if existed automatically
sends to destination..
LINKMED® HL7 TCP/IP transmitter can only be configured
to send report or query message to one IP address and one
port numbers. Multiple instances of the TCP/IP Transmitters
are needed to send query or report to more than one IP address,
call LINK Medical at 888-893-0900 or 1+ 781-453-0300 to purchase
additional license(s) of the TCP/IP Transmitter
You start the Transmitter manually during initial configuration
from your system server or from LINKMED® Interface server:
Start>LINK Medical>LINKMED® Interface>LINK
Transmitter Service
- TCP/IP Transmitter Configuration:
Before you Begin
You need the following information in order to configure
the Transmitter to send HL7 result messages and receive
HL7 acknowledgements
- The IP address of your client server to which the Transmitter
will be sending result or query message
- The port number of the server to which the Transmitter
can open a TCP/IP connection
- Filename (default is *.sen) and directory folder (default
C:\LINKMED\CFGLINK\ResultS\) of the system providing the
HL7 result or query messages
Next>>>
LINKMED® HL7 TCP/IP Transmitter window
..........................................................................................................................................................
|